Human Retinol binding protein RBP ELISA Kit

FOR RESEARCH USE ONLY

Assay range 80 μg/L -2000 μg/L 96 determinations
Purpose
This kit allows for the determination of RBP concentrations in Human serum, cell culture supernates and other biological fluids
Principle of the assay
T he kit assay Human RBP level in the sample use Purified Human RBP antibody to coat microtiter plate wells , make solid-phase antibody, then add RBP to wells , Combined antibody which With HRP labeled goat anti- Human become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human RBP in the samples is then determined by comparing the O.D. of the samples to the standard curve .
Materials provided with the k it

1
wash solution
2 0ml×1bottle
7
Stopp Solution
6 ml×1 bottle
2
HRP-Conjugate reagent
6 ml×1 bottle
8
Standard 4000μg/L
0.5ml×1 bottle
3
Microelisa stripplate
12well× 8 strips
9
Standard diluent
1.5 ml×1bottle
4
Sample diluent
6 ml×1 bottle
10
Instruction
1
5
Chromogen Solution A
6 ml×1 bottle
11
Closure plate membrane
2
6
Chromogen Solution B
6 ml×1 bottle
12
Sealed bags
1

Specimen requirements
1. extract as soon as possible after Specimen collection, and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can ’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles .
2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.
Assay procedure
1. Dilute and add sample:Dilute Original density Standard as follow table:

2000μg/L
5 Standard
150μl Original density Standard+150μl Standard diluent
1000μg/L
4 Standard
150μl 5 Standard+150μl Standard diluent
500μg/L
3 Standard
150μl 4 Standard+150μl Standard diluent
250μg/L
2 Standard
150μl 3 Standard +150μl Standard diluent
125μg/L
1 Standard
150μl 2 Standard +150μl Standard diluent

2.add sample Set blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent , other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well , then add testing sample 10μl ( sample final dilut ion is 5 -fold), add sample to well s , don’t touch the well wall as far as possible, and Gently mix.
3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37 .
4.Configurate liquid: 30-fold wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.
5.washing Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
6.add enzyme Add HRP-Conjugate reagent 50μl to each well, except  blank well.
7.incubate Operation with 3.
8.washing Operation with 5.
9. color Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37
10. Stop the reaction Add Stop Solution 50μl to each well, Stop the reaction(the blue color change to yellow color).
11. assay take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.
Steps description

Standard, Sample diluent

Add Standard, Sample diluent , incubate for 30 min at 37 .

Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37 .

Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37 .

Add Stopp Solution

Read absorbance at 450nm within 15 min

calculate

Calculate
Take the standard density as the horizontal , the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor , the result is the sample actual density.
Important notes
1. The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
2. washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
3. add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .
4. if the testing material content is excessively high er (The sample OD is bigger than the first standard well ),please dilute Sample (n -fold ), Please diluent e and multiplied by the dilution factor. ×n×5 .
5. Closure plate membrane only limits the disposable use, to avoid cross-contamination .
6. The substrate evade the light preservation.
7. Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
8. All samples, washing buffer and each kind of reject should according to infective material process.
9. Do not mix reagents with those from other lots .
Storage and validity
1 Storage  2-8℃.
2 validity six months.

上海瑞齐生物科技有限公司作者

上一篇:鸡弓形虫循环抗原(TCA)酶联免疫分析(ELISA)

下一篇:鸡传染性鼻炎抗体(IC)说明书定性


我要投稿
  • 投稿请发送邮件至:(邮件标题请备注“投稿”)[email protected]
  • 联系电话0571-87759680
环保行业“互联网+”服务平台
环保在线APP

功能丰富 实时交流

环保在线小程序

订阅获取更多服务

微信公众号

关注我们

抖音

环保在线网

抖音号:hbzhan

打开抖音 搜索页扫一扫

视频号

环保在线

公众号:环保在线

打开微信扫码关注视频号

快手

环保在线

快手ID:2537047074

打开快手 扫一扫关注
意见反馈