技术中心

人晚期糖基化终末产物受体(RAGEAGER) ELISA试剂盒

2012年05月08日 11:05:39人气:528来源:上海逸峰生物科技有限公司

资料类型 png文件 资料大小 41466
下载次数 77 资料图片 【点击查看】
上 传 人 上海逸峰生物科技有限公司 需要积分 0
关 键 词 人晚期糖基化终末产物受体,RAGEAGER,生物试剂,ELISA试剂盒
【资料简介】

FOR RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.

Human Receptor for advanced glycation end products(RAGE/AGER ELISA Kit instruction

Intended use

This RAGE/AGER ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures.The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of RAGE/AGER in the sample, this RAGE/AGER ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus RAGE/AGER concentration. The concentration of RAGE/AGER in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Sample collection and storages

Serum - Use a serum separator tube and allow samples to clot for 30 minutes before centrifugation for 10 minutes at approximay 3000×g. Remove serum and assay immediay or aliquot and store samples at -20℃ or -80℃.Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 30 minutes at 3000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.

Note: The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.

Materials required but not supplied

1. Standard microplate reader(450nm)

2. Precision pipettes and Disposable pipette tips.

3. 37 ℃ incubator

P recautions

1. D o not substit u te reagen ts fr om one kit to another. Standa rd, con juga te and m icropl a tes are m a tched for opti mal perfor mance. U se only the reagen ts supplied by manufacturer.

2. D o not remove m icropl a te from the storage bag un t il needed. Unused strips should be stored at 2 -8°C in their pouch with the desiccant prov ided.

3. Mix all reagents before using.

R emove all kit reagen ts from refriger a tor and allow them to reach room temper a ture ( 20 -25°C

Materials supplied

Name

96 determinations

48 determinations

Microelisa stripplate

12*8strips

12*4strips

Standard 2800pg/mL

0.6ml

0.6ml

Standard diluent

6.0ml

3.0ml

Sample diluent

6.0ml

3.0ml

HRP-Conjugate reagent

10.0ml

5.0ml

20X Wash solution

25ml

15ml

Chromogen Solution A

6.0ml

3.0ml

Chromogen Solution B

6.0ml

3.0ml

Stop Solution

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note: Standard diluent with Standard diluent concentration was followed by:

2800 1400 700 350 175 87.5 pg/mL

Reagent preparation

20×wash solution:Dilute with Distilled or deionized water 1:20.

Assay procedure

1. Prepa re all reagent s before starting ass ay procedure. It is recommended that all Standa rds and Sa mples be added in duplica te to the Micro elisa Stripp l a t e.

2. Add standard: Set Standard wells, testing sample wells. Add standard 50μl to standard well.

3. Add Sample: Add testing sample 10μl Then add sample diluent 40μl to testing sample well; Blank well doesn’t add anyting.

4. A dd 10 l of HRP-conjugate reagent to each well, c over with a n adhesive strip and incuba te for 60 minutes at 37°C .

4. Aspirate each well and wash, repeating the process four times for a total of f ive washes. Wash by filling each well with Wash Solution (400 μ l ) using a squirt bottle, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to goo d performance. After the last wash, remove any remaining Wash Solution by aspirating or decanting. Invert the plate and blot it against clean paper towels.

5. Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C . Protect from light .

6. Add 50 μ l Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not


appear uniform, gently tap the plate to ensure thorough mixing .

7. R ead the Optical Density O.D.) at 450 nm using a m icrotiter pl a te reader within 15 m i nutes.

C alculation of results

1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis.

2. First, calculate the mean O.D. value for each standard and sample. All O.D. values, are subtracted by the mean value of the zero standard before result interpretation. Construct the standard curve using graph paper or statistical software.

3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.

4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.

5. The sensitivity by this assay is 1.0 pg/mL.

6. Standard curve

Storage 2 -8 .

validity six months.

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!

上海逸峰生物科技有限公司作者

上一篇:不燃玻璃棉管厂家为您解析未来发展趋势

下一篇:复合玻璃棉保温板用途和 施工工艺流程


我要投稿
  • 投稿请发送邮件至:(邮件标题请备注“投稿”)[email protected]
  • 联系电话0571-87759680
环保行业“互联网+”服务平台
环保在线APP

功能丰富 实时交流

环保在线小程序

订阅获取更多服务

微信公众号

关注我们

抖音

环保在线网

抖音号:hbzhan

打开抖音 搜索页扫一扫

视频号

环保在线

公众号:环保在线

打开微信扫码关注视频号

快手

环保在线

快手ID:2537047074

打开快手 扫一扫关注
意见反馈