技术中心

您现在的位置:环保在线 > 技术首页 > 技术交流

Human Filaria IgG4 ELISA试剂盒

2011年01月14日 16:58:15人气:1139来源:上海卡努生物科技有限公司

Drug Names

Generic Name Human Filaria IgG4 ELISA Kit .

Purpose

This kit allows for the determination of Filaria IgG4 concentrations in Human serum, and other biological fluids .

Principle of the assay

T he kit assay Filaria IgG4 level in the sample use Purified Filaria IgG4 antibody to coat microtiter plate wells , make solid-phase antibody, then add Filaria IgG4 to wells , Combined With Filaria IgG4 , after washing and removing non-combinative antibody and other components , then Combined Filaria IgG4 antibody which with HRP labeled become antibody - antigen - enzyme- antibody complex, after washing Compley, Add TMB substrate solution, , TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. Compared with the CUTOFF value, according to this to judge Filaria IgG4 exist in the sample or not.

Materials provided with the k it

Materials provided with the k it

48 determinations

96 determinations

Storage

User manual

1

1

Closure plate membrane

2

2

Sealed bags

1

1

Microelisa stripplate

1

1

2 -8

Negative control

0.5ml×1 bottle

0.5ml×1 bottle

2 -8

Positive control

0.5ml×1 bottle

0.5ml×1 bottle

2 -8

HRP-Conjugate reagent

3ml×1 bottle

6ml×1 bottle

2 -8

Sample diluent

3ml×1 bottle

6ml×1 bottle

2 -8

Chromogen Solution A

3ml×1 bottle

6ml×1 bottle

2 -8

Chromogen Solution B

3ml×1 bottle

6ml×1 bottle

2 -8

Stop Solution

3ml×1 bottle

6ml×1 bottle

2 -8

wash solution

20ml × 20 fold

× 1 bottle

20ml × 30 fold

× 1 bottle

2 -8

Specimen requirements

1. serum - coagulation at room temperature 10-20 mins centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.

2. plasma - use suited EDTA or citrate plasma as an anticoagulant,mix 10-20 mins ,centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.

3. Urine -collect sue a sterile container, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again. The Operation of Hydrothorax and cerebrospinal fluid Reference to it.

4. cell culture supernatant -detect secretory components, collect sue a sterile container, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant,detect the composition of cells, Dilut cell suspension with PBS PH7.2-7.4 , Cell concentration reached 1 million / ml, repeated freeze-thaw cycles , damage cells and release of intracellular components, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.

5. Tissue samples - After cutting samples, check the weight,add PBS PH7.2-7.4 , Rapidly frozen with liquid nitrogen, maintain samples at 2-8 after melting,add PBS PH7.4 , Homogenized by hand or Grinders, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant.

6. extract as soon as possible after Specimen collection, and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can ’t, specimen can be kept in -20 to preserve, Avoid repeated freeze-thaw cycles .

7. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

Assay procedure

1. Number: to sample correspond microtitration well and Number Sequence, each plate should be set feminine comparison 2 wells, masculine comparison 2 wells, blank comparison 1 well(don’t add sample and HRP-Conjugate reagent to blank comparison well, other each step the operation are same).

2. add sample separay add Positive control and Negative control 50μl to the Positive and Negative well . add Sample dilution 40μl to testing sample well, then add testing sample 10μl. add sample to the bottom of ELISA plates coated well , don’t touch the well wall as far as possible, and Gently mix.

3. Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37 .

4. Configurate liquid: 30-foldor 20-fold)wash solution diluted 30-fold (or 20-fold) with distilled water until 6 00ml,and reserve.

5. washing Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

6. add enzyme Add HRP-Conjugate reagent 50μlto each well, except the blank well.

7. incubate Operation with 3.

8. washing Operation with 5.

9. color Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37

10. Stop the reaction Add Stop Solution 50μl to each well, Stop the reaction(the blue color change to yellow color).

11. assay take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.

Determine the result

Test validity: the average of Positive control well≥1.00; the average of Negative control well ≤0.10.

Calculate Critical(CUT OFF) : Critical= the average of Negative control well + 0 .15 .

Negative control: sample OD< Calculate Critical(CUT OFF) is Filaria IgG4 Negative control .

Positive control : ample OD≥ Calculate Critical(CUT OFF) is Filaria IgG4 Positive control .

Important notes

1. Please according to use instruction strictly, Do not mix reagents with those from other lots .

2. The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature then use, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

3. washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

4. Closure plate membrane only limits the disposable use, in order to avoid the overlapping pollution

5. The substrate please evade the light preservation.

6. The test result determination must take the microtiter plate reader as a standard, when use dual-wavelength to assay, Reference wavelength is 630nm.

7. All samples, washing buffer and each kind of reject should according to infective material process. Stopp Solution is 2M sulphuric acid. You must pay attention to safe when use .

Storage and validity

1 Storage 2-8 .

2 validity six months.


全年征稿/资讯合作 联系邮箱:[email protected]
版权与免责声明
1、凡本网注明"来源:环保在线"的所有作品,版权均属于环保在线,转载请必须注明环保在线,http://gsrxyx.com。违反者本网将追究相关法律责任。
2、企业发布的公司新闻、技术文章、资料下载等内容,如涉及侵权、违规遭投诉的,一律由发布企业自行承担责任,本网有权删除内容并追溯责任。
3、本网转载并注明自其它来源的作品,目的在于传递更多信息,并不代表本网赞同其观点或证实其内容的真实性,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品来源,并自负版权等法律责任。
4、如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系,否则视为放弃相关权利。

上海卡努生物科技有限公司作者

我要投稿
  • 投稿请发送邮件至:(邮件标题请备注“投稿”)[email protected]
  • 联系电话0571-87759680
环保行业“互联网+”服务平台
环保在线APP

功能丰富 实时交流

环保在线小程序

订阅获取更多服务

微信公众号

关注我们

抖音

环保在线网

抖音号:hbzhan

打开抖音 搜索页扫一扫

视频号

环保在线

公众号:环保在线

打开微信扫码关注视频号

快手

环保在线

快手ID:2537047074

打开快手 扫一扫关注
意见反馈