上海卡努生物科技有限公司作者
Drug Names
Generic Name
:
Human
Filaria IgG4
ELISA Kit
.
Purpose
This kit allows for the
determination of
Filaria IgG4
concentrations
in
Human
serum, and other
biological fluids
.
Principle of the assay
T
he kit
assay
Filaria IgG4
level in the
sample
,
use
Purified
Filaria IgG4
antibody to coat
microtiter plate wells
, make
solid-phase antibody, then add
Filaria IgG4
to
wells
,
Combined
With
Filaria IgG4
,
after washing and removing non-combinative antibody and other components ,
then
Combined
Filaria IgG4
antibody which with
HRP labeled
become
antibody - antigen - enzyme- antibody complex, after
washing
Compley,
Add TMB substrate solution,
,
TMB substrate becomes blue color At HRP enzyme-catalyzed,
reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm.
Compared with the CUTOFF value, according to this to judge
Filaria IgG4
exist in the
sample or not.
Materials provided with the k
it
Materials provided with the k
it
|
48 determinations |
96 determinations |
Storage |
User manual |
1 |
1 |
|
Closure plate membrane |
2 |
2 |
|
Sealed bags |
1 |
1 |
|
Microelisa stripplate |
1 |
1 |
2
|
Negative control |
0.5ml×1 bottle |
0.5ml×1 bottle |
2
|
Positive control |
0.5ml×1 bottle |
0.5ml×1 bottle |
2
|
HRP-Conjugate reagent |
3ml×1 bottle |
6ml×1 bottle |
2
|
Sample diluent |
3ml×1 bottle |
6ml×1 bottle |
2
|
Chromogen Solution A
|
3ml×1 bottle |
6ml×1 bottle |
2
|
Chromogen Solution B
|
3ml×1 bottle |
6ml×1 bottle |
2
|
Stop Solution |
3ml×1 bottle |
6ml×1 bottle |
2
|
wash solution |
(
20ml
×
20
fold
)
× 1 bottle |
(
20ml
×
30
fold
)
× 1 bottle |
2
|
Specimen requirements
1.
serum
-
coagulation at room temperature 10-20 mins
,
centrifugation 20-min
at the speed of
2000-3000 r.p.m. remove
supernatant,
If precipitation appeared,
Centrifugal again.
2.
plasma
-
use suited EDTA or citrate
plasma
as an anticoagulant,mix
10-20 mins ,centrifugation 20-min
at the speed of
2000-3000 r.p.m. remove
supernatant,
If precipitation appeared,
Centrifugal again.
3.
Urine
-collect sue a sterile container,
centrifugation 20-min
at the speed of
2000-3000 r.p.m. remove
supernatant,
If precipitation appeared,
Centrifugal again.
The
Operation of
Hydrothorax and cerebrospinal fluid Reference to it.
4.
cell culture supernatant
-detect secretory components,
collect sue a sterile container,
centrifugation 20-min
at the speed of
2000-3000 r.p.m. remove
supernatant,detect
the composition of cells, Dilut cell suspension with
PBS
(
PH7.2-7.4
)
,
Cell concentration reached 1 million / ml,
repeated freeze-thaw cycles
,
damage cells and release of intracellular components, centrifugation 20-min
at the speed of
2000-3000 r.p.m. remove
supernatant,
If precipitation appeared,
Centrifugal again.
5.
Tissue samples
-
After cutting samples, check the weight,add
PBS
(
PH7.2-7.4
)
,
Rapidly frozen with liquid nitrogen,
maintain
samples at
2
6.
extract
as soon as possible after Specimen collection,
and
according to the relevant literature, and should be
experiment as soon as possible after the extraction.
If it can
’t,
specimen can be kept in
7.
Can’t detect the sample which contain
NaN3, because
NaN3
inhibits
HRP active.
Assay procedure
1.
Number: to sample correspond
microtitration well and
Number Sequence, each plate should be set
feminine
comparison 2 wells, masculine comparison 2 wells, blank comparison 1 well(don’t add sample and
HRP-Conjugate reagent to
blank comparison well, other each step the operation
are
same).
2.
add sample
:
separay add Positive
control
and
Negative
control 50μl to the Positive
and Negative
well . add Sample dilution 40μl to testing sample well, then
add
testing sample 10μl. add sample to the bottom of
ELISA plates coated well ,
don’t touch the well wall as far as possible,
and
Gently mix.
3.
Incubate: After closing plate with
Closure plate membrane ,incubate for 30 min at
4.
Configurate liquid:
30-fold
(or 20-fold)wash solution
diluted 30-fold (or 20-fold) with distilled water
until
6
00ml,and reserve.
5.
washing
:
Uncover
Closure plate membrane,
discard
Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
6.
add enzyme
:
Add
HRP-Conjugate reagent
50μlto each well, except the blank well.
7.
incubate
:
Operation with 3.
8.
washing
:
Operation with 5.
9.
color
:
Add
Chromogen Solution A
50ul and
Chromogen Solution
B to each well,
evade the light preservation
for 15 min at
10.
Stop the reaction
:
Add
Stop Solution
50μl
to each well, Stop the reaction(the blue color change to yellow color).
11.
assay
:
take blank well as zero ,
Read absorbance at 450nm
after
Adding
Stop Solution and within 15min.
Determine the result
Test validity: the average of Positive control well≥1.00;
the average of
Negative control
well ≤0.10.
Calculate Critical(CUT OFF) : Critical= the average of
Negative control
well + 0
.15
.
Negative
control: sample OD< Calculate Critical(CUT OFF) is
Filaria IgG4
Negative
control
.
Positive
control
: ample OD≥ Calculate Critical(CUT OFF) is
Filaria IgG4
Positive
control
.
Important notes
1.
Please according to use instruction strictly,
Do not mix reagents with those from other lots
.
2.
The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature
then use,
ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
3.
washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
4.
Closure plate membrane
only limits the disposable use, in order to avoid the overlapping pollution
5.
The substrate please evade the light preservation.
6.
The test result determination must take the
microtiter plate reader
as a standard, when use dual-wavelength to assay, Reference wavelength is 630nm.
7.
All samples, washing buffer and each kind of reject should according to infective material process. Stopp Solution is
Storage and validity
1
.
Storage
:
2
2
.
validity
:
six months.
上一篇:微生物生长的几种检测方法
- 版权与免责声明
- 1、凡本网注明"来源:环保在线"的所有作品,版权均属于环保在线,转载请必须注明环保在线,http://gsrxyx.com。违反者本网将追究相关法律责任。
- 2、企业发布的公司新闻、技术文章、资料下载等内容,如涉及侵权、违规遭投诉的,一律由发布企业自行承担责任,本网有权删除内容并追溯责任。
- 3、本网转载并注明自其它来源的作品,目的在于传递更多信息,并不代表本网赞同其观点或证实其内容的真实性,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品来源,并自负版权等法律责任。
- 4、如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系,否则视为放弃相关权利。
-
型号:ST001E
-
型号:HG15- HY-3
-
型号:
-
型号:ADCI-60-W
-
型号: